Homografts versus stentless bioprosthetic valves in the pulmonary position: a multicentre propensity-matched comparison in patients younger than 20 years.



Homografts versus stentless bioprosthetic valves in the pulmonary position: a multicentre propensity-matched comparison in patients younger than 20 years.

Eur J Cardiothorac Surg. 2019 Feb 07;:

Authors: Marathe SP, Bell D, Betts K, Sayed S, Dunne B, Ward C, Whight C, Jalali H, Venugopal P, Andrews D, Alphonso N

Abstract
OBJECTIVES: The aim of this study was to compare the performance of pulmonary homografts with stentless bioprosthetic valves [Medtronic Freestyle™ (Medtronic, Minneapolis, MN, USA)] in the pulmonary position in patients with congenital heart disease (CHD) younger than 20 years.
METHODS: Between January 2000 and December 2017, 215 patients were retrospectively identified from hospital databases in 3 congenital heart centres in Australia. Valve performance was evaluated using standard criteria. Propensity score matching was used to balance the 2 treatment groups.
RESULTS: Freedom from reintervention for patients who received a pulmonary homograft (n = 163) was 96%, 88% and 81% at 5, 10 and 15 years and for patients who received a Freestyle™ valve (n = 52) was 98%, 89% and 31% at 5, 10 and 15 years, respectively. Freedom from structural valve degeneration for patients with a homograft was 92%, 87% and 77% at 5, 10 and 15 years and for patients with a Freestyle valve was 96%, 80% and 14% at 5, 10 and 15 years, respectively. In the first 10 years, there was no difference in outcomes [reintervention hazard ratios (HR) = 0.69, 95% confidence intervals (CI) (0.20-2.42), P = 0.56; structural valve degeneration HR = 0.92 (0.34-2.51), P = 0.87]. After 10 years, the recipients of the Freestyle valves were at higher risk of both outcomes [reintervention HR = 7.89; 95% CI (2.79-22.34), P < 0.001; structural valve degeneration HR = 7.41 (2.77-19.84), P < 0.001]. The findings were similar when analysed by implantation in the orthotopic position and in the propensity-matched groups.
CONCLUSIONS: The Freestyle stentless bioprosthetic valve is a comparable alternative to cryopreserved pulmonary homografts up to 10 years after implantation when implanted in an orthotopic pulmonary position in patients younger than 20 years with CHD.

PMID: 30753373 [PubMed – as supplied by publisher]

Source link





Related posts

Serotonin contribution to cardiac valve degeneration: new insights for novel therapies?

Newsemia

Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study.

Newsemia

Real Patients, Real Stories: Bill Hutchens’ Problem Solved

Newsemia

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept Read More

Privacy & Cookies Policy